Optimization and application of ICPMS with dynamic reaction cell for precise determination of <sup>44</sup>Ca/<sup>40</sup>Ca isotope ratios
- Author(s)
- Sergei F. Boulyga, Urs Klötzli, Gerhard Stingeder, Thomas Prohaska
- Abstract
An inductively coupled plasma mass spectrometer with dynamic reaction cell (ICP-DRC-MS) was optimized for determining 44Ca/40Ca isotope ratios in aqueous solutions with respect to (i) repeatability, (ii) robustness, and (iii) stability. Ammonia as reaction gas allowed both the removal of 40Ar+ interference on 40Ca + and collisional damping of ion density fluctuations of an ion beam extracted from an ICP. The effect of laboratory conditions as well as ICP-DRC-MS parameters such a nebulizer gas flow rate, rf power, lens potential, dwell time, or DRC parameters on precision and mass bias was studied. Precision (calculated using the "unbiased" or "n - 1" method) of a single isotope ratio measurement of a 60 ng g-1 calcium solution (analysis time of 6 min) is routinely achievable in the range of 0.03-0.05%, which corresponded to the standard error of the mean value (n = 6) of 0.012-0.020%. These experimentally observed RSDs were close to theoretical precision values given by counting statistics. Accuracy of measured isotope ratios was assessed by comparative measurements of the same samples by ICP-DRC-MS and thermal ionization mass spectrometry (TIMS) by using isotope dilution with a 43Ca-48Ca double spike. The analysis time in both cases was 1 h per analysis (10 blocks, each 6 min). The δ44Ca values measured by TIMS and ICP-DRC-MS with double-spike calibration in two samples (Ca ICP standard solution and digested NIST 1486 bone meal) coincided within the obtained precision. Although the applied isotope dilution with 43Ca-48Ca double-spike compensates for time-dependent deviations of mass bias and allows achieving accurate results, this approach makes it necessary to measure an additional isotope pair, reducing the overall analysis time per isotope or increasing the total analysis time. Further development of external calibration by using a bracketing method would allow a wider use of ICP-DRC-MS for routine calcium isotopic measurements, but it still requires particular software or hardware improvements aimed at reliable control of environmental effects, which might influence signal stability in ICP-DRC-MS and serve as potential uncertainty sources in isotope ratio measurements.
- Organisation(s)
- Department of Lithospheric Research
- External organisation(s)
- University of Natural Resources and Life Sciences
- Journal
- Analytical Chemistry
- Volume
- 79
- Pages
- 7753-7760
- No. of pages
- 8
- ISSN
- 0003-2700
- DOI
- https://doi.org/10.1021/ac0711790
- Publication date
- 10-2007
- Peer reviewed
- Yes
- Austrian Fields of Science 2012
- 104002 Analytical chemistry
- ASJC Scopus subject areas
- Analytical Chemistry
- Portal url
- https://ucrisportal.univie.ac.at/en/publications/8bcd9422-56f1-44cf-a571-572dec01fed5